Products


64/110kV CU/XLPE/Corrugated AL/PE(or PVC) Power Cable

Description
Construction: Compacted stranded circular or segmental copper or aluminium conductor, extruded semi-conducting compound as conductor screen, cross-linked polyethylene(XLPE) insulation, semi-conducting compound as insulation screen, semi-conducting water blocking tape, corrugated aluminium sheath, PE or PVC outer sheath.

Type

Description

No. of cores

Nominal cross section of conductor

YJLW02

Copper conductor/XLPE insulation/Corrugated aluminium sheath/PVC outer sheath Power Cable

1

240~2500mm2

YJLLW02

Aluminium conductor/XLPE insulation/Corrugated aluminium sheath/PVC outer sheath Power Cable

1

240~2500mm2

YJLW03

Copper conductor/XLPE insulation/Corrugated aluminium sheath/PE outer sheath Power Cable

1

240~2500mm2

YJLLW03

Aluminium conductor/XLPE insulation/Corrugated aluminium sheath/PE outer sheath Power Cable

1

240~2500mm2

YJLW02-Z

Copper conductor/XLPE insulation/Corrugated aluminium sheath/PVC outer sheath Longitudinal water-resistant Power Cable

1

240~2500mm2

YJLLW02-Z

Aluminium conductor/XLPE insulation/Corrugated aluminium sheath/PVC outer sheath Longitudinal water-resistant Power Cable

1

240~2500mm2

YJLW03-Z

Copper conductor/XLPE insulation/Corrugated aluminium sheath/PE outer sheath Longitudinal water-resistant Power Cable

1

240~2500mm2

YJLLW03-Z

Aluminium conductor/XLPE insulation/Corrugated aluminium sheath/PE outer sheath Longitudinal water-resistant Power Cable

1

240~2500mm2



Operating Characteristics
Rated voltage U0/U(Um): 64/110(123)kV
U0 is the rated power frequency voltage between conductor and earth or metallic screen for which the cable is designed;
U is the rated power frequency voltage between conductors for which the cable is designed;
Um is the maximum value of the “highest system voltage” for which the equipment may be used.
Max. permissible continuous operating temperature of conductor: 90 °C
Max. temperature of conductor during short-circuit (5s max. duration) shall not exceed: 250 °C
The ambient temperature under installation should not be lower than: 0 °C
The bending radius of cable: not less than 20 times of the diameter of cable


Application
The cable is laid indoors, outdoors, in tunnel, in cable trench, or direct in ground, able to bear external mechanical force and certain pulling force.


Manufacturing Standards
GB/T 11017-2002, IEC 60840


ZHEJIANG KUKUN GROUP CO., LTD.
ZHEJIANG KUKUN ELECTRIC CO., LTD.
NINGBO QRUNNING CABLE CO., LTD.
CONTACT US
Email:qrunning@kukun.com
Tel:0086-574-86198928 / 86197777
Tel:0086-13505889596
Head Office Address:NO.99 Chenshan East Road, Xiaogang, Beilun, Ningbo, China